Try barrel sauna under 5000, 13 amp hot tub, shed 8x6 or a brand.

Menu

Do you need a permit for a sauna, hot tub or shed?

What the US model codes say about your project, quoted word for word. Your city or county decides; this guide shows what to ask.

Model codes of the International Code Council (IRC, IBC and ISPSC, 2021 and 2024 editions), retrieved October 2, 2026 from codes.iccsafe.org.

What you are adding
Power and heat

What the model codes say

Permit likely needed

Under the model code, for the electrical work. Your city or county decides.

  • Building: exempt up to 200 sq ft
  • Local limit: some cities use 120 sq ft
  • Electrical: permit likely

3 points for a sauna: 2 from the code text, 1 our reading. Details and code text below.

Permit likely needed. 3 points for a sauna: 2 from the code text, 1 our reading. Exempt. Building permit: exempt in the model code up to 200 sq ft. Depends. Your city may use a lower limit, such as 120 sq ft. Permit likely. Electrical work: a permit under the model code.

  1. Exempt: Building permit: exempt in the model code up to 200 sq ft

    A one-story detached sauna building of 80 sq ft falls under the exemption. It only waives the permit: the building must still meet the code and local rules such as zoning.

    Other than storm shelters, one-story detached accessory structures, provided that the floor area does not exceed 200 square feet (18.58 m2).

    Code text, IRC 2021 and 2024, R105.2, Building item 1; IRC 2021 and 2024, R105.2

  2. Depends: Your city may use a lower limit, such as 120 sq ft

    States and cities adopt the codes with their own changes. The International Building Code (IBC) exempts only tool and storage sheds, playhouses and similar uses up to 120 sq ft. Some cities use 120 sq ft for homes too, each with its own scope: Durango, Colorado, for any one-story detached accessory structure; Urbandale, Iowa, only for sheds, playhouses and similar uses without a permanent foundation.

    One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided that the floor area is not greater than 120 square feet (11 m2).

    Code text, IBC 2021 and 2024, 105.2, Building item 1; Durango, Colorado, 2024 IRC Amendments, R105.2 (1); Urbandale, Iowa, Code of Ordinances, 150.03(B)(2)(a)

  3. Permit likely: Electrical work: a permit under the model code

    R105.1 asks for a permit to install any electrical system the code regulates. The electrical exemptions in R105.2 cover only small jobs, such as replacing lamps or plugging approved portable equipment into an existing receptacle. A hard-wired heater or a new dedicated circuit is not among them.

    Any owner or owner’s authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the building official and obtain the required permit.

    Our reading, IRC 2021 and 2024, R105.1; IRC 2021 and 2024, R105.2, Electrical item 5

Check with your city or county building department

They decide, under the code edition your state or city has adopted and its local changes.

  1. Find it: search for your city's name and "building permit". Outside city limits, ask your county. USA.gov lists the local governments of every state.
  2. Ask which edition of the IRC applies there and whether it changed the permit exemptions in R105.2.
  3. Ask about zoning as well: distance to the property line, height and lot coverage are local rules, with or without a building permit.
  4. Have the floor area, the heater's power and voltage, and the installation manual at hand.

This guide quotes the model codes and marks our own reading of them; it is not legal advice.

The code text behind this guide

Building permits in the US are issued by cities and counties under codes their state or city adopts and may change. The International Code Council writes the model codes quoted here and states that All fifty states, the District of Columbia, and many other countries have adopted the I-Codes at the state or jurisdictional level. They are the International Residential Code (IRC) for homes and their accessory structures (R101.2), and the International Swimming Pool and Spa Code (ISPSC) for pools and spas. The electrical rules quoted here are from Chapter 42 of the IRC, which names the matching article of the National Electrical Code in brackets; we have not checked the NEC text itself.

Code textSection
All fifty states, the District of Columbia, and many other countries have adopted the I-Codes at the state or jurisdictional level.International Code Council, I-Codes overview
The provisions of this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height with a separate means of egress and their accessory structures not more than three stories above grade plane in height.IRC 2021, R101.2
Any owner or owner’s authorized agent who intends to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the building official and obtain the required permit.IRC 2021 and 2024, R105.1
Exemption from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction.IRC 2021 and 2024, R105.2
Other than storm shelters, one-story detached accessory structures, provided that the floor area does not exceed 200 square feet (18.58 m2).IRC 2021 and 2024, R105.2, Building item 1
Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles.IRC 2021 and 2024, R105.2, Electrical item 5
Portable heating appliances.IRC 2021 and 2024, R105.2, Mechanical item 1
Self-contained refrigeration systems containing 10 pounds (4.54 kg) or less of refrigerant or that are actuated by motors of 1 horsepower (746 W) or less.IRC 2021 and 2024, R105.2, Mechanical item 7
The design and construction of pools and spas shall comply with the International Swimming Pool and Spa Code.IRC 2021, R327.1
The design and construction of pools and spas shall comply with the International Swimming Pool and Spa CodeIRC 2024, R328.1
POOL. Manufactured or field-constructed equipment designed to contain water on a permanent or semipermanent basis and used for swimming, wading, immersion, or therapeutic purposes.IRC 2021, E4201.2, Pool
The outlet(s) that supplies a self-contained spa or hot tub, or a packaged spa or hot tub equipment assembly, or a field-assembled spa or hot tub shall be protected by a ground-fault circuit interrupter.IRC 2021 and 2024, E4208.1 (refers to NEC 680.44)
Each of such means shall be readily accessible and within sight from the equipment it serves and shall be located not less than 5 feet (1524 mm) horizontally from the inside walls of a pool, spa, or hot tub unless separated from the open water by a permanently installed barrier that provides a 5-foot (1524 mm) or greater reach path.IRC 2024, E4203.3 (refers to NEC 680.13)
Any owner, or owner’s authorized agent who desires to construct, enlarge, alter, repair, move, or demolish a pool or spa or to erect, install, enlarge, alter, repair, remove, convert or replace any system, the installation of which is regulated by this code, or to cause any such work to be performed, shall first make application to the code official and obtain the required permit for the work.ISPSC 2021 and 2024, 105.1
SPA. A product intended for the immersion of persons in temperature-controlled water circulated in a closed system, and not intended to be drained and filled with each use.ISPSC 2021 and 2024, Chapter 2, Spa
ELEVATED POOL.Any permanently installed pool, spa, cold plunge, catch basin, overflow trough, including any connected water feature, or body of water water feature, that is over a habitable, occupiable or unoccupied space that is (1) inside a thermal envelope, (2) outside a thermal envelope, or (3) a combination of inside and outside the thermal envelope.ISPSC 2024, Chapter 2, Elevated pool
Where spas or hot tubs are equipped with a lockable safety cover complying with ASTM F1346 and swimming pools are equipped with a powered safety cover that complies with ASTM F1346, the areas where those spas, hot tubs or pools are located shall not be required to comply with Sections 305.2 through 305.7.ISPSC 2021 and 2024, 305.1
Outdoor pools and spas and indoor swimming pools shall be surrounded by a barrier that complies with Sections 305.2.1 through 305.7.ISPSC 2021 and 2024, 305.2
The top of the barrier shall be not less than 48 inches (1219 mm) above grade where measured on the side of the barrier that faces away from the pool or spa.ISPSC 2021 and 2024, 305.2.1, item 1
Detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height with a separate means of egress, and their accessory structures not more than three stories above grade plane in height, shall comply with this code or the International Residential Code.IBC 2021, 101.2, Exception
One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided that the floor area is not greater than 120 square feet (11 m2).IBC 2021 and 2024, 105.2, Building item 1
Other than storm shelters one story detached accessory structures, provided that the floor area does not exceed 120 square feet.Durango, Colorado, 2024 IRC Amendments, R105.2 (1)
One story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 120 square feet and the structure does not utilize a permanent foundation.Urbandale, Iowa, Code of Ordinances, 150.03(B)(2)(a)

Saunas and plunges by power supply

Which saunas plug into a standard outlet and which need a 240 V circuit: 120 V vs 240 V saunas. Listings with seats, voltage and price: sauna finder and cold plunge finder.